跳至主要内容

Safety Precautions Before Operation Of Sewage Suction Truck

 

5CBM vacuum truck


1. Before uncovering the inlet of the feed tank, the sewage suction truck needs to open the pressure relief valve to discharge the excess air in the tank;

2. Clean the tachometer probe right away;

3. Check the safety valve to ensure that the exhaust starts at 0.196MPA, and the pressure in the tank must not exceed 0.16MPA;

4. Check whether the sprinkler tachometer is working properly, so as not to damage the ball air compressor and power take-off due to overturning;

5. Pay attention to whether the pressure gauge of the sprinkler is working normally, and prevent the pressure gauge from malfunctioning and overpressure explosion;

6. Listen to the sound of the air compressor rotating from the power take-off of the sewage suction truck. If the sound is abnormal, stop the machine immediately to eliminate the fault.

Matters needing attention in the use and maintenance of sewage suction truck:


sewage tank truck

1. No air leakage is allowed in the pipeline of the sewage suction truck, otherwise the heavy duty sewage suction truck will not work.

2. The big bucket of the sewage suction truck must be equipped with an anti-overflow device, otherwise it is easy to suck the fecal sewage into the vacuum pump when the sewage suction truck is used, and damage the entire system.

3. The oil return port of the first-class oil-gas separator of the sewage suction truck is connected to the oil-return port of the second-class oil-gas separator, and the oil suction pipe must be a hard pipe or a hard oil-resistant rubber pipe (steel braided rubber hose). Plastic pipes deformed by heat are not allowed.

4. When the multifunctional sewage suction truck is used in a new pump, 1-2 liters of N32 mechanical oil should be directly added to the pump, and 32 refrigerating oil should be added to the pump in cold areas in the northeast and northwest.

5. A water-gas separator should be installed at the suction port of the pump.

评论

此博客中的热门博文

How to Prevent Hydraulic Oil From Emulsifying On Concrete Mixer Truck?

The main cause of hydraulic oil emulsification on concrete mixer truck s is water in the hydraulic system, which is mixed with water after a long time. The removed hydraulic oil will form an emulsification of the hydraulic oil. We found that water enters the hydraulic system due to the following reasons: a. Working in a humid environment, the moisture in the air condenses due to the alternation of cold and heat, turning into water droplets and falling into the oil; b. The rainwater on the fuel tank seeps into the fuel tank due to the weak sealing of welding and connection parts; c.  Due to the damage of the pumping cylinder seal and the damage of the mixing motor, moisture is brought into the oil; d. Daily maintenance, cleaning, oil change, and maintenance process bring in moisture. To prevent the oil from emulsifying, we must first prevent moisture from entering the hydraulic system. When the car leaves the factory, the welding and connection parts must be manufactured in accord...

What is a flatbed semi trailer?

  A   flatbed semi trailer   is a very useful platform that is used in the shipping industry. It is primarily used for the transportation of shipping containers of different sizes. This is a long flat platform of either 20ft, 40ft, 48ft or 53ft length used for carrying shipping containers.  The flatbed semi trailer has no roof or walls to the side. It is a bare platform on which different container sizes are secured using container locks ready for transportation.The size of the FengYuan flatbed semi trailer loading area is determined according to the standard container size. A twist lock device for fixing the container is provided at positions corresponding to the four corners of the bottom of the container. However, it can also be used to take up other different types of loads. These different types of flatbed trailers have different capabilities and usefulness for various applications as discussed in here. Understanding their operations and basic specification...

Installation Guide of Turbo Charger

Please install your turbochargers according to our following installation guide in order to avoid some unnecessary damages. *Pre-Installation 1. Change new recommended quality oil & air filters. 2. Change recommended engine oil. 3. Pre-oil the turbo oil inlet. 4. Change new oil inlet pipes or flush the oil inlet pipes to remove flakes or carbon deposits. 5. Ensure oil supply of at least 0.5kgf/m2 or 7 psi within 3 seconds 1st engine start (if possible, use oil gauge to measure). 6. Mount turbine inlet to engine manifold 7. Attach oil inlet pipe to turbo and crank the engine a few times until oil flows out of the turbo oil drain. Then attach the oil drain pipe. 8. Connect remaining air piping hose. 9. Ensure that all bolts, screws & nuts are tightened. 10. Allow engine to idle for 5 minutes before operating at higher rpm. 11. Check for unusual noises and leaks 12. Do not operate the turbo if you suspect any problems. Consult us immediately. ...